QuickTies™

Masonry QuickTies™

QTBM Blue, QTGM Green, QTOM Orange, QTRM Red

QTBM Blue
ALLOWABLE LOAD: 2,102 LB

PRESTRESS LOAD: 2,940 LB
Wire Rope:
Breaking Strength: 4,200lb
Hole Diameter:
Top Plate: 1″
Concrete³: 7/16″
Concrete³:
Min. Comp. Strength: 2500 psi
Min. Embedment: 4″
Min. Edge Distance: 4″
TER 1404-06; FL #17106

QTGM Green
ALLOWABLE LOAD: 3,504 LB

PRESTRESS LOAD: 4,900 LB
Wire Rope:
Breaking Strength: 7,000 lb
Hole Diameter:

Top Plate: 1″
Concrete³: 9/16″
Concrete³:

Min. Comp. Strength: 2500 psi
Min. Embedment: 4″
Min. Edge Distance: 4″
TER 1404-06; FL #17106

QTOM Orange
ALLOWABLE LOAD: 4,905 LB

PRESTRESS LOAD: 6,860 LB
Wire Rope:
Breaking Strength: 9,800 lb
Hole Diameter:

Top Plate: 1″
Concrete³: 3/4″
Concrete³:

Min. Comp. Strength: 2500 psi
Min. Embedment: 6-5/8″
Min. Edge Distance: 4″
TER 1404-06; FL #17106

QTRM Red
ALLOWABLE LOAD: 7,207 LB
PRESTRESS LOAD: 10,080 LB
Wire Rope:
Breaking Strength: 14,400 lb
Hole Diameter:

Top Plate: 1″
Concrete³: 7/8″
Concrete³:

Min. Comp. Strength: 2500 psi
Min. Embedment: 8-1/8″
Min. Edge Distance: 4″
TER 1404-06; FL #17106

Product Sheet

Drawing Details

Typical Installation

Video Installations

Contact us today and talk to your regional sales rep and explore how we can help you build faster and safer.

Download

Product Catalog Spring 2024